Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 32
Filter
1.
Chinese Journal of Cardiology ; (12): 257-262, 2022.
Article in Chinese | WPRIM | ID: wpr-935137

ABSTRACT

Objective: To analyze the safety and efficacy of combined left atrial appendage (LAA) and patent foramen ovale (PFO) closure in adult atrial fibrillation (AF) patients complicating with PFO. Methods: This study is a retrospective and cross-sectional study. Seven patients with AF complicated with PFO diagnosed by transesophageal echocardiography (TEE) in Zhoupu Hospital Affiliated to Shanghai University of Medicine & Health Sciences from June 2017 to October 2020 were selected. Basic data such as age, gender and medical history were collected. The atrial septal defect or PFO occluder and LAA occluder were selected according to the size of PFO, the ostia width and depth of LAA. Four patients underwent left atrial appendage closure(LAAC) and PFO closure at the same time. PFO closure was performed during a one-stop procedure of cryoablation combined with LAAC in 2 patients. One patient underwent PFO closure at 10 weeks after one-stop procedure because of recurrent transient ischemic attack (TIA). All patients continued to take oral anticoagulants. TEE was repeated 8-12 weeks after intervention. In case of device related thrombus(DRT), TEE shall be rechecked 6 months after adjusting anticoagulant and antiplatelet drug treatment. Patients were follow-up at 1, 3, 6, 12, 24 months by telephone call, and the occurrence of cardio-cerebrovascular events was recorded. Results: Among the 7 patients with AF, 2 were male, aged (68.0±9.4) years, and 3 had a history of recurrent cerebral infarction and TIA. Average PFO diameter was (3.5±0.8)mm. Three patients were implanted with Watchman LAA occluder (30, 30, 33 mm) and atrial septal defect occluder (8, 9, 16 mm). 2 patients were implanted with LAmbre LAA occluder (34/38, 18/32 mm) and PFO occluder (PF1825, PF2525). 2 patients were implanted with LACbes LAA occluder (24, 28 mm) and PFO occluder (PF2525, PF1825) respectively. The patients were followed up for 12 (11, 24) months after operation. TEE reexamination showed that the position of LAA occluder and atrial septal defect occluder or PFO occluder was normal in all patients. DRT was detected in 1 patient, and anticoagulant therapy was adjusted in this patient. 6 months later, TEE showed that DRT disappeared. No cardiovascular and cerebrovascular events occurred in all patients with AF during follow-up. Conclusions: In AF patients complicated with PFO, LAAC combined with PFO closure may have good safety and effectiveness.


Subject(s)
Adult , Aged , Humans , Male , Middle Aged , Atrial Appendage/surgery , Atrial Fibrillation/surgery , Cardiac Catheterization/methods , China , Cross-Sectional Studies , Foramen Ovale, Patent/surgery , Retrospective Studies
2.
Rev. bras. cir. cardiovasc ; 36(5): 717-719, Sept.-Oct. 2021. tab, graf
Article in English | LILACS | ID: biblio-1351648

ABSTRACT

Abstract Although many anatomical variations may be encountered in children with double outlet right ventricle, coexistence of levo-malposed great vessels and left juxtaposed atrial appendages is uncommonly observed. This case report underlines the rarity of this anatomical combination and its clinical significance along with the surgical management in an infant.


Subject(s)
Humans , Infant , Child , Transposition of Great Vessels/diagnostic imaging , Double Outlet Right Ventricle/surgery , Double Outlet Right Ventricle/diagnostic imaging , Atrial Appendage/surgery , Atrial Appendage/diagnostic imaging , Heart Defects, Congenital/surgery , Heart Defects, Congenital/diagnostic imaging , Arteries
4.
Chinese Journal of Medical Instrumentation ; (6): 355-360, 2021.
Article in Chinese | WPRIM | ID: wpr-888623

ABSTRACT

At present, the standard left atrial appendage occlusion procedure mainly involves two-dimensional imaging methods such as X-ray fluoroscopy and transesophageal echocardiography to guide the operation, which will lead to underestimation of the three dimensional structure of the left atrial appendage and the surrounding tissue, thus adversely affects the surgery. To solve this problem, a surgery assist system for left atrial appendage occlusion based on preoperative cardiac CT images is developed. The proposed system realizes the left atrial appendage parameter measurement based on cardiac CT image, and realizes the calculation of optimal delivery sheath trajectory and three-dimensional simulation of the delivery sheath movement on the basis of a novel delivery sheath trajectory model. The system is expected to provide precise guidance for left atrial appendage occlusion, improve the success rate and safety of the operation, and at the same time help reduce the difficulty of learning the operation, and facilitate the promotion of left atrial appendage occlusion.


Subject(s)
Humans , Atrial Appendage/surgery , Atrial Fibrillation/surgery , Cardiac Catheterization , Echocardiography, Transesophageal , Tomography, X-Ray Computed , Treatment Outcome
5.
Chinese Journal of Cardiology ; (12): 880-885, 2021.
Article in Chinese | WPRIM | ID: wpr-941371

ABSTRACT

Objective: To evaluate the safety and effectiveness of left atrial appendage occlusion (LAAO) in patients with atrial fibrillation and end-stage renal disease undergoing long-term hemodialysis. Methods: Six patients with AF and end-stage renal disease(ESRD)on long term hemodialysis who underwent LAAO from March 2017 to March 2021 in Beijing Anzhen Hospital were enrolled. Baseline characteristics such as age, sex, types of arrhythmia, stroke and bleeding score, and continuous dialysis time were collected. Four patients underwent LAAO, two patients underwent the combined procedure of catheter ablation and LAAO. Perioperative treatment and serious complications were recorded. Transesophageal echocardiography was repeated at 45 days and 60 days after the procedure. Telephone follow-up was conducted at 3, 6 and 12 months after the procedure, and every 6 months thereafter. Thromboembolism and major bleeding events and survival were evaluated. Results: The average age was (66.7±17.0) years old, and 5 were male (5/6). There were 4 patients with paroxysmal AF (4/6), and 2 patients with persistent AF (2/6). The mean CHA2DS2-VASc score was (4.8±1.5), and the HAS-BLED score was (3.5±1.4). The duration of hemodialysis was 2.6 (1.1, 8.3) years. Successfully Watchman implantation was achieved in all patients. There were no severe perioperative complications, and no device related thrombosis or leaks were observed by transesophageal echocardiography. During a mean of 22.0 (12.0, 32.0) months follow-up, there was no thromboembolism or major bleeding events. A total of 2 patients died, one from sudden cardiac death, and another one from heart failure. Conclusions: LAAO may be a safe and effective therapeutic option for prevention of thromboembolism in patients with atrial fibrillation and end-stage renal disease undergoing long-term hemodialysis, further studies with larger patient cohort are needed to confirm our results.


Subject(s)
Aged , Aged, 80 and over , Humans , Male , Middle Aged , Atrial Appendage/surgery , Atrial Fibrillation/surgery , Echocardiography, Transesophageal , Kidney Failure, Chronic/therapy , Renal Dialysis , Stroke , Thromboembolism , Treatment Outcome
6.
Rev. bras. cir. cardiovasc ; 35(6): 999-1002, Nov.-Dec. 2020. tab, graf
Article in English | LILACS, SES-SP | ID: biblio-1143991

ABSTRACT

Abstract Minimally invasive surgical ablation is generally contraindicated in patients with atrial fibrillation and thrombosis of the left atrial appendage. We have treated three of these patients using an innovative technique based on a bilateral video-thoracoscopic approach, performing a continuous encircling lesion at the pulmonary veins outflow with radio-frequency ablation, simultaneously excluding the left atrial appendage. The postoperative course was uneventful, without neurologic events and all patients maintained a stable sinus rhythm at 1-year follow-up. This procedure represents a new mini-invasive method to treat persistent atrial fibrillation when partial thrombosis of the left atrial appendage contraindicates other ablation techniques.


Subject(s)
Humans , Atrial Fibrillation/surgery , Thrombosis/etiology , Catheter Ablation , Atrial Appendage/surgery , Atrial Appendage/diagnostic imaging , Thoracoscopy , Treatment Outcome
7.
Rev. bras. cir. cardiovasc ; 35(5): 841-843, Sept.-Oct. 2020. tab, graf
Article in English | SES-SP, LILACS | ID: biblio-1137322

ABSTRACT

Abstract Cardiac rhythm disorders are common in many patients with cancer. The management of synchronous long-standing persistent atrial fibrillation and pulmonary lesions remains a serious surgical dilemma due to the lack of clinical data and surgical guidelines. To the best of our knowledge, this is the first described case of simultaneous thoracoscopic pulmonary segmentectomy and left atrial posterior wall and pulmonary vein isolation combined with left atrial appendage resection in a patient with early-stage primary lung cancer and long-standing persistent atrial fibrillation.


Subject(s)
Humans , Female , Aged , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Catheter Ablation/methods , Adenocarcinoma, Mucinous/surgery , Adenocarcinoma, Mucinous/complications , Adenocarcinoma, Mucinous/diagnostic imaging , Pneumonectomy/methods , Pulmonary Veins/surgery , Thoracoscopy , Tomography, X-Ray Computed , Treatment Outcome , Atrial Appendage/surgery , Heart Atria/surgery , Lung Neoplasms/surgery , Lung Neoplasms/complications , Lung Neoplasms/diagnostic imaging
8.
Rev. bras. cir. cardiovasc ; 35(4): 577-579, July-Aug. 2020. tab, graf
Article in English | LILACS, SES-SP | ID: biblio-1137308

ABSTRACT

Abstract Early recognition and rapid and appropriate treatment of cardiac tamponade are mandatory to prevent the irreversible deterioration of cerebral perfusion and other important organs. In this study, cardiac tamponade was induced by inadvertent transseptal puncture, which was managed with pericardial drainage and surgical repair in a patient with symptomatic paroxysmal atrial fibrillation. Epicardial atrial fibrillation ablation and left atrial appendage amputation were also performed at the same time.


Subject(s)
Humans , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Cardiac Tamponade/etiology , Cardiac Tamponade/diagnostic imaging , Atrial Appendage/surgery , Atrial Appendage/diagnostic imaging , Cardiac Tamponade/surgery , Treatment Outcome , Catheter Ablation , Catheters , Amputation, Surgical
9.
Rev. invest. clín ; 72(2): 103-109, Mar.-Apr. 2020. tab, graf
Article in English | LILACS | ID: biblio-1251841

ABSTRACT

ABSTRACT Background: The left atrial appendage (LAAp) resection is an effective treatment approach to reduce the risk of thromboembolism in patients with atrial fibrillation. Objective: To study was to study the impact of removing atrial appendages in the production of natriuretic peptides (NPs) in conditions of volume overload and to develop an experimental model of LAAp resection. Materials and Methods: In a swine model of ischemic heart failure (HF), serum NP levels were measured before (Basal-1A) and after (Basal-1B) a fluid overload. Animals were grouped as follows: (0) preserved appendages, (1) resected LAAp, and (2) both atrial appendages resected. Levels of NP were measured before (2A) and after a fluid overload (2B). Results: Furin levels were higher in Group 0-2A than in Group 2-2A, and a significant increase was found in Group 0-2B compared to Groups 1-2B and 2-2B. Corin levels increased in Basal-1B versus Basal-1A. Atrial NP (ANP) decreased in Basal-1B compared to Basal-1A. After HF induction, ANP increased in Groups 2-2A and 2-2B. Conclusions: Resection of atrial appendages drastically modifies the natriuretic mechanisms of cardiac homeostasis, especially after a fluid overload challenge. Herein, we describe the face and predictive validation of an animal model of atrial appendage resection useful to investigations in translational medicine.


Subject(s)
Animals , Male , Atrial Appendage/surgery , Atrial Appendage/metabolism , Disease Models, Animal , Heart Failure/surgery , Heart Failure/metabolism , Homeostasis , Swine , Natriuretic Peptides/biosynthesis , Natriuretic Peptides/physiology , Academic Medical Centers
10.
Journal of Southern Medical University ; (12): 1415-1421, 2020.
Article in Chinese | WPRIM | ID: wpr-880761

ABSTRACT

OBJECTIVE@#To investigate the effect of the combination of atrial fibrillation (AF) ablation and left atrial appendage closure (LAAC) on cardiac function and the success rate of AF ablation.@*METHODS@#We retrospectively analyzed the data of 56 patients with AF undergoing a one-stop procedure for AF ablation and LAAC in our hospital between May, 2015 and May, 2019. Propensity score matching (PSM) at the ratio of 1:1 was used to select 56 control patients undergoing AF ablation at high risk of stroke, for matching with the hybrid procedure group. The perioperative complications, thromboembolic events, recurrence of atrial arrhythmia and cardiac function were compared between the groups.@*RESULTS@#The two groups of patients were comparable for age, gender, BMI, duration and type of AF, concomitant diseases, CHA2DS2-VASc and HAS-BLED scores (@*CONCLUSIONS@#The combination of AF ablation and LAAC is safe but does not improve the success rate of AF ablation. The one-stop procedure can improve cardiac function of the patients, but AF ablation alone can achieve better improvement of cardiac function.


Subject(s)
Humans , Atrial Appendage/surgery , Atrial Fibrillation/surgery , Catheter Ablation , Retrospective Studies , Treatment Outcome
11.
Chinese Journal of Cardiology ; (12): 859-865, 2020.
Article in Chinese | WPRIM | ID: wpr-941190

ABSTRACT

Objective: To analyze the electrophysiological characteristics and the therapeutic efficacy of irrigated-tip catheter radiofrequency ablation(RFA) without radiation for pregnant women with focal atrial tachycardia(AT) originating from the right atrial appendage (RAA). Methods: Data from 55 women with focal AT, who underwent radiofrequency ablation (RFA) in the First Affiliated Hospital of Zhengzhou University from October 2016 to March 2019, were screened. 2 non-pregnant women with right atrial appendage tachycardia (RAAT) and 4 pregnant women with non-RAAT were excluded. The remaining 49 cases were divided into RAAT during pregnancy group (n=6, including 4 cases of tachycardia-induced cardiomyopathy) and non-pregnant and non-RAAT group (control, n=43). Under the guidance of three-dimensional mapping system, the earliest activation site was identified, RFA with the irrigated catheter without x-ray fluoroscopy was performed in RAAT patients during pregnancy, all patients in control group underwent non-zero-ray ablation. Patients were followed up at 3, 6, 12 months post procedure, and yearly follow up thereafter in outpatient clinic. Electrocardiogram or Holter monitoring was performed during follow up. AT recurrence and surgical complications were recorded during follow up. At 6 months after RFA, echocardiography examination and laboratory examination including N-terminal B-type brain natriuretic peptide measurement were performed in the pregnant patients, delivery results were also recorded in the pregnant patients. The electrophysiological characteristics of RAAT during pregnancy were analyzed, the therapeutic efficacy of RFA was compared between the two groups. Results: This study is a retrospective study. Age ((30.7±6.2)years vs. (57.2±11.7)years), left ventricular ejection fraction ((46.0±12.8)% vs. (60.1±5.9)%), proportions of organic heart disease (0% vs. 58%) were significantly lower in the RAAT patients during pregnancy group than in control group (P<0.05), while proportions of patients with persistent tachycardia (100% vs. 7%), symptoms of chest distress and palpitation (6/6 vs. 49%) and left ventricular ejection farction≤50% (4/6 vs. 9%) were significantly higher in RAAT group than in control group (P<0.05), heart rate was similar between the two groups ((163.7±11.1)beats/minutes vs. (153.7±15.2)beats/minutes, P>0.05). The characteristic P-wave morphology was observed in RAAT patients during pregnancy, i.e, P wave was mostly upright (5/6) in inferior-leads (Ⅱ, Ⅲ, aVF) and in lead I and aVL, deep and wide negative P wave was found in V1 lead (5/6), and gradually became positive from V2-V6. The mean tachycardia cycle length was (361.7±38.5) ms. Three-dimensional mapping showed that the origin points of the 6 RAAT pregnant patients were all scattered in the local region, the local region was ablated accordingly, 2 patients (2/6) received extensive ablation of local areas. Immediate successful rate was similar between the two groups (6/6 vs. 93%). During follow up ((15.3±4.0) months), no complications were observed after RFA, postoperative recurrence rate was similar (1/6 vs. 12%). Uncomplicated delivery was reported in all 6 pregnant RAAT post ablation. Normal cardiac structure and function was observed in the 4 pregnant patients with tachycardia-induced cardiomyopathy post ablation. Compared to pre-ablation phase, reduced left atrial dimension ((30.3±1.3) mm vs. (36.8±6.7) mm, P>0.05), increased left ventricular ejection fraction ((64.0±2.9)% vs. (39.8±10.7)%), reduced left ventricular end-diastolic dimension ((44.8±4.0) mm vs. (60.0±2.9) mm) and reduced N-terminal B-type natriuretic peptide value ((136.2±47.5) ng/L vs. (3 408.4±901.3) ng/L) were observed at 6 months post ablation (P<0.05). Conclusion: The electrophysiological characteristics are suggestive for focal AT originating from RAA during pregnancy. Under the guidance of 3-dimension activation mapping, no fluoroscopic RFA with irrigated-tip catheter is a safe and effective strategy for the treatment of focal RAAT during pregnancy.


Subject(s)
Female , Humans , Pregnancy , Atrial Appendage/surgery , Retrospective Studies , Stroke Volume , Tachycardia , Treatment Outcome , Ventricular Function, Left
12.
Chinese Journal of Cardiology ; (12): 842-847, 2020.
Article in Chinese | WPRIM | ID: wpr-941187

ABSTRACT

Objective: We aimed to explore the feasibility and perioperative safety of performing catheter ablation and left atrial appendage closure (LAAC) in a single (one-stop) session in patients with atrial fibrillation (AF). Methods: This study is an observational study. Consecutive AF patients who underwent the combined procedure of catheter ablation and LAAC with Watchman device of Xinhua Hospital in Shanghai between March 2017 and May 2019 were prospectively enrolled. Baseline, intra-and peri-procedural parameters were evaluated. Results: A total of 358 AF patients (189 males, (69.0±8.0) years) underwent the one-stop procedure. The CHA2DS2-VASc score was 3.2±1.5 and HAS-BLED score was 2.4±1.1, respectively in this patient cohort. Pulmonary vein isolation was achieved in all patients, while additional linear ablation was applied in 180 (50.3%) patients, yielding immediate success rate of 99.7%. Successful Watchman implantation was achieved in all patients. The perioperative serious adverse event occurred in 14 cases (3.9%). including 6 pericardial effusions (1.7%), 1 stroke (0.3%) and 5 vascular complications (1.4%), yielding procedure-related complication rate of 3.4%. In addition, 2 (0.6%) new-onset heart failures occurred postoperatively. There was no major bleeding or death during the perioperative period. Conclusions: Combined catheter ablation and LAAC can be successfully and safely performed in AF patients with high stroke risk. Follow-up data are needed to evaluate the outcome of this one-stop procedure.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Atrial Appendage/surgery , Catheter Ablation , China , Feasibility Studies , Treatment Outcome
14.
Rev. méd. Chile ; 147(10): 1350-1354, oct. 2019. graf
Article in Spanish | LILACS | ID: biblio-1058605

ABSTRACT

We report a 65-years old woman with a history of permanent atrial fibrillation with high risk for ischemic and bleeding events. She developed a heart failure with severely impaired left ventricular ejection fraction and severe secondary mitral regurgitation. Given her high surgical risk, using transesophageal echocardiography guidance, a concomitant deployment of two MitraClip devices using a high-posterior septal puncture and a left atrial appendage closure with an Amplatzer Amulet occluder were performed through the same access.


Subject(s)
Humans , Female , Aged , Atrial Fibrillation/surgery , Heart Valve Prosthesis Implantation/methods , Atrial Appendage/surgery , Septal Occluder Device , Mitral Valve Insufficiency/surgery , Severity of Illness Index , Angiography/methods , Risk Factors , Treatment Outcome , Echocardiography, Transesophageal
15.
Arq. bras. cardiol ; 113(4): 712-721, Oct. 2019. tab, graf
Article in English | LILACS | ID: biblio-1038571

ABSTRACT

Abstract Background: Left atrial appendage (LAA) occlusion is an alternative therapy for atrial fibrillation patients who have high embolic risk and contraindications to anticoagulant therapy. Objective: To evaluate the feasibility, safety, and mid-term outcomes of percutaneous LAA occlusion, including device-related thrombosis. Methods: Sixty consecutive patients who had undergone percutaneous LAA occlusion with AMPLATZER™ Amulet™ device from September 2015 to March 2018 were enrolled. Patients were followed for 21 ± 15 months (median - 20 months, interquartile range - 9 to 27 months). The postprocedural assessment was done at the 1(st), 6(th), and 12(th) month. Patients were clinically evaluated, and transesophageal echocardiography was performed at each visit. We evaluated the condition of normality of variables using the Kolmogorov-Smirnov test. P-values < 0.05 were statistically significant. Results: The most common indication for the procedure was major bleeding with anticoagulants (n: 53, 88.3%). The procedure was completed successfully in 59 (98.3%) patients. Periprocedural mortality was observed in one patient. Postprocedural antiplatelet treatment was planned as dual or single antiplatelet therapy or low-dose anticoagulant therapy in 52 (88.1%), 2 (3.4%), and 5 (8.5%) patients, respectively. We found no clinically significant cerebrovascular events, device-related thrombus, or embolization in any patient during the follow-up. Two (3.4 %) patients presented significant peri-device leak (>3 mm) at the 1st month evaluation, which disappeared at the 12th month follow-up. Conclusion: We concluded that LAA occlusion using the Amulet™ LAA occluder can be performed with high procedural success and acceptable outcomes.


Resumo Fundamento: A oclusão do apêndice atrial esquerdo (AAE) é uma terapia alternativa para pacientes com fibrilação atrial que tenham alto risco embólico e contraindicações à terapia anticoagulante. Objetivo: Avaliar a viabilidade, segurança e resultados de médio prazo da oclusão percutânea do AAE, incluindo a trombose relacionada à prótese. Métodos: Sessenta pacientes consecutivos que foram submetidos à oclusão percutânea do AAE com a prótese AMPLATZER™ Amulet™ de setembro de 2015 a março de 2018 foram incluídos no estudo. Os pacientes foram acompanhados por 21 ± 15 meses (mediana - 20 meses, intervalo interquartílico - 9 a 27 meses). A avaliação pós-procedimento foi feita no 1º, 6º e 12º mês. Os pacientes foram examinados clinicamente e um ecocardiograma transesofágico foi realizado a cada visita. A condição de normalidade das variáveis foi avaliada por meio do teste de Kolmogorov-Smirnov. Os valores de p < 0,05 foram considerados estatisticamente significativos. Resultados: A indicação mais comum para o procedimento foi sangramento significativo com anticoagulantes (n: 53, 88,3%). O procedimento foi concluído com sucesso em 59 (98,3%) pacientes. Mortalidade peri-procedimento ocorreu em um paciente. A tratamento antiplaquetário pós-procedimento foi planejado como terapia antiplaquetária única ou dupla ou terapia anticoagulante de dose baixa em 52 (88,1%), 2 (3,4%) e 5 (8,5%) pacientes, respectivamente. Não foram encontrados eventos cerebrovasculares clinicamente significativos, trombo relacionado à prótese ou embolização nos pacientes durante o seguimento. Dois (3,4%) pacientes apresentaram vazamento peri-prótese significativo (>3 mm) na avaliação do 1º mês, que desapareceu no 12º mês de seguimento. Conclusão: Concluiu-se que a oclusão do AAE com o oclusor de AAE Amulet™ pode ser realizada com grande sucesso e resultados aceitáveis.


Subject(s)
Humans , Male , Female , Middle Aged , Aged , Aged, 80 and over , Atrial Fibrillation/therapy , Cardiac Catheterization/methods , Atrial Appendage/surgery , Septal Occluder Device , Thromboembolism/prevention & control , Platelet Aggregation Inhibitors/therapeutic use , Echocardiography , Tomography, X-Ray Computed , Retrospective Studies , Risk Factors , Follow-Up Studies , Treatment Outcome , Echocardiography, Transesophageal , Risk Assessment , Atrial Appendage/diagnostic imaging , Stroke/prevention & control , Hemorrhage/chemically induced , Anticoagulants/adverse effects
16.
Rev. bras. cir. cardiovasc ; 34(4): 495-498, July-Aug. 2019. tab, graf
Article in English | LILACS | ID: biblio-1020498

ABSTRACT

Abstract Management of symptomatic atrial tachycardia (AT) during pregnancy seems challenging, especially those originating from left atrial appendage (LAA), which easily tend to be incessant and mediate cardiomyopathy. It's contradictory between therapy and pregnancy. In this study, we report a case of a woman who presented with persistent AT, which lead to heart failure, during early pregnancy. She underwent successful catheter ablation using CartoSound and electroanatomic mapping without fluoroscopy. An electrophysiology (EP) study confirmed a focal LAA tachycardia. Soon after, left ventricular function of her heart normalized, and the patient successfully delivered a healthy child.


Subject(s)
Humans , Female , Pregnancy , Adult , Pregnancy Complications, Cardiovascular/surgery , Atrial Fibrillation/surgery , Catheter Ablation/methods , Atrial Appendage/surgery , Pregnancy Complications, Cardiovascular/diagnostic imaging , Atrial Fibrillation/diagnostic imaging , Atrial Appendage/diagnostic imaging , Electrocardiography , Electrophysiology
17.
Arq. bras. cardiol ; 109(6): 541-549, Dec. 2017. tab, graf
Article in English | LILACS | ID: biblio-887988

ABSTRACT

Abstract Background: Atrial fibrillation (AF) is a cardiac arrhythmia with high risk for thromboembolic events, specially stroke. Objective: To assess the safety of left atrial appendage closure (LAAC) with the Amplatzer Cardiac Plug for the prevention of thromboembolic events in patients with nonvalvular AF. Methods: This study included 15 patients with nonvalvular AF referred for LAAC, 6 older than 75 years (mean age, 69.4 ± 9.3 years; 60% of the male sex). Results: The mean CHADS2 score was 3.4 ± 0.1, and mean CHA2DS2VASc , 4.8 ± 1.8, evidencing a high risk for thromboembolic events. All patients had a HAS-BLED score > 3 (mean, 4.5 ± 1.2) with a high risk for major bleeding within 1 year. The device was successfully implanted in all patients, with correct positioning in the first attempt in most of them (n = 11; 73.3%). Conclusion: There was no periprocedural complication, such as device migration, pericardial tamponade, vascular complications and major bleeding. All patients had an uneventful in-hospital course, being discharged in 2 days. The echocardiographic assessments at 6 and 12 months showed neither device migration, nor thrombus formation, nor peridevice leak. On clinical assessment at 12 months, no patient had thromboembolic events or bleeding related to the device or risk factors. In this small series, LAAC with Amplatzer Cardiac Plug proved to be safe, with high procedural success rate and favorable outcome at the 12-month follow-up. (Arq Bras Cardiol. 2017; [online].ahead print, PP.0-0)


Resumo Fundamento: Fibrilação atrial (FA) é uma arritmia cardíaca que submete os pacientes a alto risco de eventos tromboembólicos, particularmente o acidente vascular encefálico. Objetivo: Avaliar a segurança da oclusão do apêndice atrial esquerdo (OAAE) com o dispositivo Amplatzer Cardiac Plug na prevenção de fenômenos embólicos em pacientes com FA de origem não valvar. Métodos: Este estudo de OAAE incluiu 15 pacientes, sendo 6 (40%) acima de 75 anos (idade média, 69,4 ± 9,3 anos; 60% do sexo masculino). Resultados: A média do escore CHADS2 foi 3,4 ± 0,1. Quando se aplicou o CHA2DS2VASc, a média foi de 4,8 ± 1,8, mostrando alto risco de eventos tromboembólicos. Todos os pacientes tinham o escore HAS-BLED > 3 (média 4,5 ± 1,2) com alto risco de sangramentos maiores em 1 ano. Houve sucesso no implante do dispositivo em todos os pacientes, com posicionamento correto na primeira tentativa na maioria deles (n = 11; 73,3%). Conclusão: Não houve complicações periprocedimento, como migração do dispositivo, tamponamento pericárdico, complicações vasculares e hemorragias maiores. Na fase intra-hospitalar, os pacientes evoluíram favoravelmente, obtendo alta em até 2 dias. Nas avaliações ecocardiográficas do seguimento em 6 e 12 meses, não houve migração do dispositivo, presença de trombos e nem vazamentos peridispositivo. Na evolução clínica aos 12 meses, nenhum dos pacientes apresentou eventos tromboembólicos ou sangramentos relacionados aos fatores de risco ou ao dispositivo. Nesta pequena série, a OAAE mostrou-se segura, com uma alta taxa de sucesso do procedimento e evolução favorável dos pacientes aos 12 meses. (Arq Bras Cardiol. 2017; [online].ahead print, PP.0-0)


Subject(s)
Humans , Male , Female , Aged , Atrial Fibrillation/prevention & control , Thromboembolism/prevention & control , Cardiac Catheterization/instrumentation , Atrial Appendage/surgery , Septal Occluder Device , Thrombosis , Retrospective Studies , Longitudinal Studies , Atrial Appendage/diagnostic imaging , Equipment Safety
18.
Rev. bras. cir. cardiovasc ; 32(6): 517-522, Nov.-Dec. 2017. tab, graf
Article in English | LILACS | ID: biblio-897953

ABSTRACT

Abstract Nonvalvular atrial fibrillation is associated with a 4- to 5-fold strokes increase and may be responsible for 15% to 20% of all strokes in the elderly. In this scenario, the left atrial appendage thrombus would be the associated with 90% of cases. The use of anticoagulants, percutaneous devices, and the left atrial appendage surgical exclusion is still an open discussion. For left atrial appendage procedures, relevant anatomic spatial relationships have to be emphasized, besides the chance of the normal physiological functioning would be eliminated with the proceedings. There are evidences that the left atrial appendage closure during routine cardiac surgery is significantly associated with an increased risk of early postoperative atrial fibrillation. Therefore, the purpose of this review is to focus basic aspects for continuous medical education. In summary, the rationale of this text is to emphasize anatomical and pharmacological aspects involved in the simple surgical exclusion of left atrial appendage under cardiopulmonary bypass. There are several operative techniques, but to conclude this revision it will present one of them based on the discussed basic sciences.


Subject(s)
Humans , Atrial Fibrillation/surgery , Atrial Appendage/surgery , Stroke/prevention & control , Cardiac Surgical Procedures/education , Atrial Fibrillation/complications , Cardiopulmonary Bypass , Risk Factors , Treatment Outcome , Evidence-Based Medicine , Atrial Appendage/physiology , Stroke/etiology , Education, Medical, Continuing , Cardiac Surgical Procedures/methods , Anticoagulants/therapeutic use
19.
Arch. cardiol. Méx ; 87(4): 286-291, oct.-dic. 2017. tab
Article in Spanish | LILACS | ID: biblio-887538

ABSTRACT

Resumen: Objetivo: Demostrar que la resección quirúrgica de la orejuela izquierda en los pacientes con enfermedad reumática mitral y fibrilación auricular persistente de larga evolución disminuye la posibilidad de embolia cerebral. Asimismo, esto también elimina la necesidad de anticoagulación oral a largo plazo. Método: Se estudiaron en forma observacional y prospectiva 27 pacientes adultos con enfermedad reumática mitral y fibrilación auricular persistente de larga evolución, sometidos a cirugía valvular mitral y resección quirúrgica de la orejuela izquierda. La anticoagulación oral con warfarina fue suspendida después del tercer mes postoperatorio, recibiendo solamente aspirina a largo plazo. El punto final fue la ausencia de embolia cerebral. Secundariamente, se evaluó la formación de trombos en la aurícula izquierda por ecocardiografía transtorácica postoperatoria. Resultados: Después del tercer mes, ningún paciente presentó embolia cerebral. Un paciente exhibió isquemia cerebral transitoria dentro de los primeros 3 meses en tratamiento con warfarina. Secundariamente, en la cirugía se encontró trombo en aurícula izquierda en 11 casos (40.7%). De estos 11, 6 (54.5%) habían tenido embolia cerebral previamente, sin encontrar significación estadística (p = 0.703). Conclusiones: Este estudio muestra que pudiera haber indicios de que la orejuela izquierda pueda ser la principal fuente embolígena en la enfermedad reumática mitral, y que su resección pueda eliminar el riesgo de embolia cerebral en pacientes con enfermedad reumática mitral y fibrilación auricular persistente de larga evolución.


Abstract: Objective: To demonstrate that surgical removal of the left atrial appendage in patients with rheumatic mitral valve disease and long standing persistent atrial fibrillation decreases the possibility of stroke. This also removes the need for long-term oral anticoagulation after surgery. Method: A descriptive, prospective, observational study was conducted on 27 adult patients with rheumatic mitral valve disease and long standing persistent atrial fibrillation, who had undergone mitral valve surgery and surgical removal of the left atrial appendage. Oral anti-coagulation was stopped in the third month after surgery. The end-point was the absence of embolic stroke. An assessment was also made of postoperative embolism formation in the left atrium using transthoracic echocardiography. Results: None of the patients showed embolic stroke after the third post-operative month. Only one patient exhibited transient ischaemic attack on warfarin therapy within the three postoperative months. Left atrial thrombi were also found in 11 (40.7%) cases during surgery. Of these, 6 (54.5%) had had embolic stroke, with no statistical significance (P = .703). Conclusions: This study suggests there might be signs that the left atrial appendage may be the main source of emboli in rheumatic mitral valve disease, and its resection could eliminate the risk of stroke in patients with rheumatic mitral valve disease and long-standing persistent atrial fibrillation.


Subject(s)
Humans , Male , Female , Middle Aged , Atrial Fibrillation/surgery , Atrial Fibrillation/complications , Atrial Appendage/surgery , Embolism/etiology , Embolism/prevention & control , Mitral Valve , Rheumatic Heart Disease/surgery , Rheumatic Heart Disease/complications , Prospective Studies , Stroke/etiology , Stroke/prevention & control
20.
Arq. bras. cardiol ; 109(5): 440-447, Nov. 2017. tab, graf
Article in English | LILACS | ID: biblio-887971

ABSTRACT

Abstract Background: Left atrial appendage closure (LAAC) is an effective alternative to oral anticoagulation (OA) for the prevention of stroke in patients with non-valvular atrial fibrillation (NVAF). Objective: To present the immediate results and late outcomes of patients submitted to LAAC and included in the Brazilian Registry of Percutaneous Left Atrial Appendage Closure. Methods: 91 patients with NVAF, high stroke risk (CHA2DS2VASc score = 4.5 ± 1.5) and restrictions to OAC (HAS-BLED score = 3.6 ± 1.0) underwent 92 LAAC procedures using either the Amplatzer cardiac plug or the Watchman device in 11 centers in Brazil, between late 2010 and mid 2016. Results: Ninety-six devices were used (1.04 device/procedure, including an additional non-dedicated device), with a procedural success rate of 97.8%. Associated procedures were performed in 8.7% of the patients. Complete LAAC was obtained in 93.3% of the successful cases. In cases of incomplete closure, no residual leak was larger than 2.5 mm. One patient needed simultaneous implantation of 2 devices. There were 7 periprocedural major (5 pericardial effusions requiring pericardiocentesis, 1 non-dedicated device embolization and 1 coronary air embolism without sequelae) and 4 minor complications. After 128.6 patient-years of follow-up there were 3 deaths unrelated to the procedure, 2 major bleedings (one of them in a patient with an unsuccessful LAAC), thrombus formation over the device in 2 cases (both resolved after resuming OAC for 3 months) and 2 strokes (2.2%). Conclusions: In this multicenter, real world registry, that included patients with NVAF and high thromboembolic and bleeding risks, LAAC effectively prevented stroke and bleeding when compared to the expected rates based on CHA2DS2VASc and HASBLED scores for this population. Complications rate of the procedure was acceptable considering the beginning of the learning curve of most of the involved operators.


Resumo Fundamento: A oclusão percutânea do apêndice atrial esquerdo (OAAE) é uma alternativa eficaz à anticoagulação oral (ACO) para a prevenção de acidente vascular cerebral (AVC) em pacientes com fibrilação atrial não-valvular (FANV). Objetivo: Apresentar os resultados imediatos e o seguimento tardio de pacientes submetidos a OAAE e incluídos no Registro Brasileiro de Oclusão Percutânea do Apêndice Atrial Esquerdo. Métodos: 91 pacientes com FANV, alto risco de AVC (escore CHA2DS2VASc = 4,5 ± 1,5) e restrição à AO (escore HAS-BLED = 3,6 ± 1,0) foram submetidos a 92 procedimentos de OAAE com as próteses Amplatzer Cardiac Plug e Watchman em 11 centros do Brasil, entre o final de 2010 e a metade de 2016. Resultados: Utilizaram-se 96 próteses no total (1,04 próteses/procedimento, incluindo-se o uso de 1 prótese não-dedicada adicional em um dos casos), obtendo-se sucesso em 97,8% dos procedimentos. Realizaram-se procedimentos associados à OAAE em 8,7% dos pacientes. Observou-se oclusão total do AAE em 93,3% dos casos com sucesso, e nos casos de oclusão incompleta, nenhum leak foi > 2,5 mm. Um paciente necessitou do implante simultâneo de 2 próteses. Houve 7 complicações maiores periprocedimento (5 derrames pericárdicos necessitando pericardiocentese, 1 embolização da prótese não-dedicada e 1 embolia aérea coronariana sem sequelas) e 4 menores. No seguimento de 128,6 pacientes-ano, houve 3 óbitos não relacionados ao procedimento, 2 sangramentos maiores (um deles em um dos casos de insucesso da OAAE), formação de trombo sobre a prótese em 2 casos (tratados com sucesso com reinstituição da ACO por 3 meses), e 2 AVCs (2,2%). Conclusões: Neste registro multicêntrico de mundo real, que incluiu pacientes com FANV e alto risco de sangramento e de eventos tromboembólicos, a OAAE foi eficaz na prevenção de AVC e sangramento quando comparada às taxas de AVC previstas pelos escores CHA2DS2VASc e HASBLED para esta população. O índice de complicações do procedimento foi aceitável, considerando se tratar do início da curva de aprendizado da maioria dos operadores envolvidos.


Subject(s)
Humans , Male , Female , Aged , Atrial Fibrillation/surgery , Atrial Appendage/surgery , Stroke/prevention & control , Septal Occluder Device , Atrial Fibrillation/diagnostic imaging , Follow-Up Studies , Treatment Outcome , Echocardiography, Transesophageal , Atrial Appendage/diagnostic imaging , Stroke/etiology
SELECTION OF CITATIONS
SEARCH DETAIL